HouYuan & Benovor Vertical Autoclave With Counter Pressure

HouYuan & Benovor Vertical Autoclave With Counter Pressure

The VS-EF series vertical back pressure rapid cooling autoclave (sterilizer) uses saturated steam as the sterilization medium, discharges the air in the cavity by gravity displacement, and uses saturated steam under high pressure to kill all microorganisms. The unique jacket water cooling system can achieve rapid cooling after sterilization. This sterilizer is suitable for sterilization.
With built-in printer, with counter pressure, with F0.

Facebook
Twitter
LinkedIn

Main Features:

Adopting microcomputer control technology and touch screen operation, the whole process (heating, sterilization, exhaust, drying) is automatically programmed. 

♦ The touch screen automatically displays the operating process status, temperature, pressure, time and other parameters as well as fault alarm information.

♦ Built-in liquid load, culture medium, custom and other sterilization programs for users to choose.

♦ Counter pressure protection system: external compressed air is used during the cooling stage to ensure that the sterilized items are effectively protected.

♦ Air cooling.

♦ Equipped with a micro printer to record the entire sterilization process and fault alarm information in real time.

♦ Buzzer prompts when the program cycle ends and the fault alarm occurs.

♦ It has the function of automatic detection and correction of atmospheric pressure, which is convenient for installation, commissioning and equipment operation in plateau and low-atmosphere areas.

Safety devices:

♦ Over-temperature automatic protection device: When the set temperature is exceeded, the system automatically cuts off the power supply.

♦ Door safety interlock device: With electronic door lock, the sterilizer can only start the working procedure when the door is closed in place. If there is pressure in the inner room or the power is not connected, the electronic door lock locks the door handle and the door cannot be opened.

♦ Door temperature safety interlock device: When the liquid load is sterilized, the door can only be opened when the liquid load temperature drops to a safe temperature (lower than the local boiling point -20℃), avoiding the risk of liquid explosion in accordance with the requirements of “TSG 21-2016 Technical Supervision Regulations for Safety of Fixed Pressure Vessels” and GB4793.4.

♦ Anti-dry burning alarm device: When the water level is lower than the low water level, the heating power supply is automatically cut off and the alarm information is displayed.

Safety valve for automatic pressure relief of overpressure: When the set pressure is exceeded, the safety valve opens to release the pressure.

Electronic circuit safety device: DC control circuit with overvoltage and overload protection, AC main circuit with short circuit protector.

Main Parameters:

ModelVS-50EFVS-80EFVS-100EFVS-120EFVS-150EF
Chamber mmΦ316×667Φ386×700Φ386×900Φ500×620Φ500×780
Volume50L80L100L120L150L
Design Pressure0.3Mpa
Design Temperature150℃
Rated Working Pressure0.23Mpa
Temperature Range105~136℃
Temperature Accuracy0.1℃
Temperature Uniformity≤±0.5℃
Max. Working Temperature136℃
Power SupplyAC220~240V,50/60HzAC220~240V,50/60HzAC220~240V,50/60HzAC220~240V/380V,50/60HzAC220~240V/380V,50/60Hz
Machine Size mm476×636×990546×710×1030546×710×1220780×850×1020780×850×1180
Net Weight Kg8696112180210

Additional information

Send Us Message

Customize the product for your idea.